Escape Sense: Does the building around you meet the rules?

News Related Keywords: No tags.

First, song and dance entertainment show entertainment venues

1. Evacuation door between two safety exits ≤ 25m .

2. Evacuation doors ≤ 9m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 1.4m .

Second, the high-level hotels, hotel buildings 1 , evacuation doors located between two safety exits ≤ 30m .

2, located on both sides of the aisle or to make a pouch-shaped end of the evacuation door ≤ 15m.

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The distance between the light evacuation indicator signs is ≤ 20m ; for the bag-shaped walkway ≤ 10m ; and the walkway corner area is ≤ 1.0m .

4, door width: escape doors and emergency exits clear width of ≥ 0.9m.

Third, single, multi-storey teaching building

1. The evacuation door between two safety exits is ≤ 35m .

2. Evacuation doors ≤ 22m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 1.4m .

Fourth, high-rise teaching buildings

1. Evacuation door between two safety exits ≤ 30m .

2. Evacuation doors ≤ 15m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 1.4m .

V. Nursery, Kindergarten and Senior Citizens Buildings

1. Evacuation door between two safety exits ≤ 25m .

2. Evacuation doors ≤ 20m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 0.9m .

Six, single, multi-layer medical buildings

1. The evacuation door between two safety exits is ≤ 35m .

2. Evacuation doors ≤ 20m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 0.9m . ( 1.4 meters at the clinic hall )

Seventh, high-rise medical buildings

1. Evacuation door between two safety exits ≤ 30m .

2. Evacuation doors ≤ 15m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 0.9m . (outpatient hall 1.4 meters )

Eighth, high-rise medical building wards

1. Evacuation door between two safety exits ≤ 24m .

2. Evacuation doors ≤ 12m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 0.9m . ( 1.4 meters at the clinic hall )

9. Large space buildings such as auditoriums, exhibition halls, multi-function halls, restaurants, business halls, etc.

1, auditorium, exhibition hall, function rooms, restaurants, business offices, etc., at any point in its interior doors or evacuation to the nearest safe exit of the straight-line distance ≤ 30m; when the evacuation door is not straight or the ground outside the evacuation stairwell should be used An evacuation walkway with a length of no more than 10m leads to the nearest safety exit. When the site is equipped with an automatic sprinkler system, the safety evacuation distance from any point in the room to the nearest safety exit can be increased by 25% .

Tenth, high-rise exhibition building

1. Evacuation door between two safety exits ≤ 30m .

2. Evacuation doors ≤ 15m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 1.4m .

Eleven, other buildings (single, multi-layer)

1. Evacuation door between two safety exits ≤ 40m .

2. Evacuation doors ≤ 22m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 0.9m .

Twelve other high-rise buildings

1. Evacuation door between two safety exits ≤ 40m .

2. Evacuation doors ≤ 20m on both sides or at the end of the bag-shaped walkway .

3 , evacuation instruction signs: a , should be set in the safety exit and densely populated places directly above the evacuation door b , should be set in the evacuation aisle and its corner at a height of 1.0m from the ground wall or on the ground. The spacing of the lights evacuation signs is ≤ 20m ; for the bag-shaped walkways, ≤ 10m ; in the corners of the walkways, ≤ 1.0m .

4. The net width of the door: The net width of the evacuation door and safety exit is ≥ 0.9m .