KCG-10 / 0.6 high temperature gear pump maintenance should pay attention to the problem

KCG-10 / 0.6 type high temperature gear pump maintenance should pay attention to the problem: 1. The pipeline and the junction with or without loose phenomenon. Hand turning KCG-10 / 0.6 high temperature gear pump KCG-10 / 0.6 type high temperature gear pump is flexible. 2. Add bearing lubricating oil to the bearing body, observe the oil level should be at the center line of the oil, the lubricating oil should be replaced or replenished promptly. 3. Unscrew the diversion plug of KCG-10 / 0.6 high-temperature gear pump body, and pour water (or slurry). 4. Close the outlet valve and outlet pressure gauge and import vacuum gauge. 5. Jog the motor to see if the motor is turning correctly. 6. Start the motor. After the KCG-10 / 0.6 high-temperature gear pump is operating normally, open the outlet pressure gauge and the inlet vacuum pump to see the proper pressure. Gradually open the gate valve and check the motor load. 7. Try to control the flow and head of KCG-10 / 0.6 high temperature gear pump within the range indicated on the plate to ensure that KCG-10 / 0.6 high temperature gear pump can work at maximum efficiency to get the maximum energy saving effect. 8.KCG-10 / 0.6 high temperature gear pump during operation, the bearing temperature can not exceed the ambient temperature 35C, the maximum temperature shall not exceed 80C. 9. If you find KCG-10 / 0.6 high temperature gear pump abnormal sound should stop immediately check the reasons. 10.KCG-10 / 0.6-type high-temperature gear pump to stop using, first close the gate valve, pressure gauge, and then stop the motor. 11.KCG-10 / 0.6 high temperature gear pump in the first month of work, after 100 hours to replace the oil, after each 500 hours, oil change time. 12. Regularly adjust the packing gland to ensure normal drip leakage in the packing room (it is advisable to leak into a drop). 13. Check the wear and tear of the shaft sleeve regularly, should be promptly replaced after larger wear. 14.KCG-10 / 0.6 type high temperature gear pump used in winter season, after parking, you need to unscrew the lower part of the drain plug to drain the media to the net. Prevent cracking. 15.KCG-10 / 0.6 type high temperature gear pump long-term deactivation, the pump should be all open, dry the water, the rotating parts and joints coated with grease installed, properly protected.

Pipette Stand

Carousel Pipettor Stand,Micro Pipette Carousel,Micro Pipettor Stand,Plastic Linear Pipettor Holder

Taizhou TOPAID Medical Device Co,,ltd , https://www.topaidbio.com