Hebei Kitty-Boat Marine Power Flexible Cable, DA, SA Difference

DA is a single vertical combustion experiment, SA is a bunched cable combustion experiment, its combustion experiment method is different, DA type experimental device is relatively simple, SA is more complex, are the representation of the test cable combustion performance, bunched cable combustion experiment It is more rigorous than the single vertical burning test, and it is also high in the non-flammable performance of the cable. Therefore, the SA cable is better than the DA cable. However, both are Type A, which means that the gases produced by combustion are toxic, acidic, and smokey. Today's marine cables are developing in the direction of DC and SC. They are halogen-free, low-toxic, and environmentally friendly.

CEFR rubber jacket soft cable CEFR, CEFR cable First, the implementation of the standard: GB9331.2-88 Second, use: This product is suitable for all kinds of rivers and ships and offshore oil platforms and other water structures for transmission of electrical energy. 0316-5962888 3, the use of features: long-term allowable cable temperature is 85 °C, rated voltage Uo / U is 0.6/1KV. The minimum bending radius of the cable during laying is as follows: The metal shielding armor type is 6 times the outer diameter of the cable. Non-armoured type, when the outer diameter is less than or equal to 25mm, it is 4 times of the outer diameter of the cable, and more than 25mm is 6 times of the outer diameter of the cable. Fourth, the model name CEFR/DA EPR insulation neoprene sheathed shipboard power soft cable, DA type, connected with mobile electrical appliances. Fifth, technical requirements 1, should be able to withstand one-way 30,000 curve test. 2, the cable should be able to withstand the AC voltage 3500V or DC 8400V, 5min does not breakdown. 3, cable core structure, insulation resistance, insulation and sheath thickness and weight shall comply with the provisions of GB9331.2-88. Six, delivery requirements 1, cable delivery length of three cores and below and the conductor cross-section is not more than 2.5 square, should not be less than 150 meters, other cables 100 meters. 2. Short-length cables with a length of not less than 20 meters are allowed to be delivered, but their quantity should not exceed 10% of the delivery length. 3, according to the agreement between the parties allow any length of cable delivery. 4. The length error should not exceed +-0.5%.

First, the scope of application

This product can be used in accordance with the needs of users of ethylene propylene insulation, cross-linked polyethylene insulation, PVC insulation, natural - butyl benzene insulation production of marine power cable. It is mainly applied to the power, lighting and general control devices of various water structures such as various river and sea vessels and offshore oil platforms.

This product is suitable for power systems with rated voltage U0/U of 0.6/1kV and below.

Second, the cable structure diagram is as follows:

Third, the use of features
1. The rated voltage U0/U is 0.6/1kV and below power system. The maximum allowable operating temperature for cable conductors is:

EPR insulated shipboard power cable is 90°C

Cross-linked polyethylene insulated marine power cable is 90°C

PVC insulated shipboard power cable 70°C

Natural butyl benzene insulated shipboard power cable 65°C

2. When the short circuit (maximum duration does not exceed 5S) the maximum temperature of the cable conductor does not exceed:

Ethylene propylene insulated shipboard power cable is 250°C

Cross-linked polyethylene insulated marine power cable is 250°C

PVC insulated marine power cable 150°C

Natural butyl benzene insulated shipboard power cable 150°C

3. The laying temperature of XLPE insulated and PVC insulated cables should not be lower than 0°C. The minimum bending radius of single-core cable is 20D, and the multi-core cable is 15D (D is the cable outer diameter). The temperature for laying of EPR insulated, natural-butyl-benzene insulated marine cables shall not be lower than 0°C. The minimum bend radius shall be 10D for single-core cables and 6D for multi-core cables (D shall be the outer diameter of cables).

Fourth, the cable model and name are shown in Table 1 to 4.

Table 1 Epoxy Insulated Marine Power Cables Common Models Product Models Product Name CEF/DA/SA/NA

CEF80/DA/SA/NA

CEF82/DA/SA/NACEF90/DA/SA/NA

CEF92/DA/SA/NA

CEFR/DA/SA/NA EPR insulation neoprene sheathed shipboard power cable, DA type/SA type/NA type EPR insulated neoprene sleeve bare copper braided armored shipboard power cable, DA type/SA type/NA -type EPR insulated neoprene inner sheathed copper wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type EPR insulated neoprene inner sheathed bare steel wire braided shipboard power cable, DA type/SA type /NA Type EPR insulated neoprene inner sheathed steel wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type EPR insulated neoprene sheathed shipboard electric power flexible cable, DA type/SA type/NA type CEH/DA/SA/NA

CEH80/DA/SA/NA

CEH90/DA/SA/NA

CEH82/DA/SA/NA

CEH92/DA/SA/NA

CEHR/DA/SA/NA EPR insulated chlorosulfonated polyethylene sheathed marine power cable, DA type/SA type/NA type EPR insulated chlorosulfonated polyethylene inner sheathed bare copper wire braided shipboard power cable, DA Type/SA Type/NA Type Ethylene-Propylene Insulation Chlorosulfonated Polyethylene Inner Naked Steel Wire Braid Armored Marine Power Cable, DA Type/SA Type/NA Type Ethylene-Propylene Insulated Chlorosulfonated Polyethylene Inner Bushing PVC vinyl jacket marine power cable, DA type/SA type/NA type ethylene propylene insulated chlorosulfonated polyethylene inner sheathed steel wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type ethylene propylene insulation Polyethylene Sheath Marine Power Flexible Cable, DA/SA/NA CEV/DA/SA/NA

CEV80/DA/SA/NA

CEV90/DA/SA/NA

CEV92/DA/SA/NA

CEV82/DA/SA/NA

CEVR/DA/SA/NA EPR insulated PVC sheathed marine power cable, DA type/SA type/NA type EPR insulated PVC inner sheathed bare copper wire braided shipboard power cable, DA type/SA type /NA type EPR insulated PVC inner sheathed bare steel wire braided shipboard power cable, DA type/SA type/NA type EPR insulated PVC inner sheathed wire braided armored PVC outer sheathed shipboard power cable, type DA /SA type/NA type EPR insulated PVC inner sheathed copper wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type EPR insulated PVC sheathed shipboard electric power flexible cable, type DA /SA type/NA type CEPF/SC/NC/NSC

CEPF80/SC/NC/NSC

CEPF86/SC/NC/NSC

CEPF90/SC/NC/NSC

CEPF96/SC/NC/NSC

CEPFR/SC/NC/NSC halogen-free low-smoke EPR insulated thermoplastic polyolefin sheathed flame-retardant shipboard power cable, SC/NC/NSC type halogen-free low-smoke ethylene propylene insulated thermoplastic polyolefin sheathed bare copper wire braid Fire-retardant shipboard power cable, SC/NC/NSC halogen-free low-smoke EPR insulated thermoplastic polyolefin inner sheathed copper wire braided thermoplastic polyolefin jacket flame-retardant shipboard power cable, SC type/NC type/NSC type Halogen-free low smoke ethylene propylene insulated thermoplastic polyolefin sheathed bare steel braided armored flame retardant shipboard power cable, SC/NC/NSC halogen-free low smoke ethylene propylene insulated thermoplastic polyolefin sheathed steel wire braided thermoplastic polyolefin Flame-retardant shipboard power cable, SC type/NC type/NSC type halogen-free low-smoke EPR insulated thermoplastic polyolefin sheathed flame-retardant shipboard power flexible cable, SC type/NC type/NSC type CEPJ/SC/NC/NSC

CEPJ80/SC/NC/NSC

CEPJ85/SC/NC/NSC

CEPJ90/SC/NC/NSC

CEPJ95/SC/NC/NSC

CEPJR/SC/NC/NSC halogen-free low smoke EPR insulated cross-linked polyolefin sheathed flame-retardant shipboard power cable, SC type/NC type/NSC type halogen-free low smoke EPR insulation crosslinked polyolefin inner sheath bare copper wire Woven flame-retardant shipboard power cable, SC/NC/NSC type halogen-free low-smoke ethylene propylene insulated cross-linked polyolefin inner sheathed copper wire braided armored cross-linked polyolefin sheathed flame-retardant shipboard power cable, SC type/NC /NSC type halogen-free and low smoke EPR insulated cross-linked polyolefin inner sheathed bare steel wire braided flame-retardant shipboard power cable, SC/NC/NSC halogen-free low smoke EPR insulated crosslinked polyolefin inner sheathed steel wire Woven cross-linked polyolefin sheathed flame-retardant shipboard power cable, SC type/NC type/NSC type halogen-free low smoke EPR insulated cross-linked polyolefin sheathed flame-retardant shipboard power flexible cable, SC type/NC type/NSC type Note: The cable types not listed in this table can be composed according to the Q/NPDL035-2006 standard.

Table 2 Cross-linked Polyethylene Insulated Marine Power Cables Common Models Product Models Product Name CJV/DA/SA/NA

CJV80/DA/SA/NA

CJV82/DA/SA/NA

CJV90/DA/SA/NA

CJV92/DA/SA/NA

CJVR/DA/SA/NA cross-linked polyethylene insulated PVC sheathed marine power cable, DA type/SA type/NA type cross-linked polyethylene insulated PVC inner sheathed bare copper wire braided shipboard power cable, DA Type/SA type/NA type cross-linked polyethylene insulated PVC inner sheathed copper wire braided PVC outer sheathed marine power cable, DA type/SA type/NA type cross-linked polyethylene insulated PVC inner sheathed bare steel wire Woven armored marine power cable, DA type/SA type/NA type crosslinked polyethylene insulated PVC inner sheathed steel wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type crosslinked polyethylene insulation PVC sheathed shipboard power flexible cable, DA type/SA type/NA type CJPF/SC/NC/NSC

CJPF80/SC/NC/NSC

CJPF86/SC/NC/NSC

CJPF90/SC/NC/NSC

CJPF96/SC/NC/NSC

CJPFR/SC/NC/NSC halogen-free low smoke cross-linked polyethylene insulated thermoplastic polyolefin sheathed flame-retardant shipboard power cable, SC/NC/NSC halogen-free low-smoke cross-linked polyethylene insulated thermoplastic polyolefin inner sheath bare Copper wire braided flame-retardant shipboard power cable, SC/NC/NSC type halogen-free low-smoke cross-linked polyethylene insulated thermoplastic polyolefin inner sheathed copper wire braided armored thermoplastic polyolefin sheathed flame-retardant shipboard power cable, SC type /NC/NSC Halogen-free Low Smoke Crosslinked Polyethylene Insulated Thermoplastic Polyolefin Inner Naked Wire Braid Armored Flame-retardant Marine Power Cable, SC/NC/NSC Halogen-free Low Smoke Crosslinked Polyethylene Insulation Thermoplastic Poly. Inner sheathed steel wire braided armored thermoplastic polyolefin sheathed flame retardant marine power cable, SC/NC/NSC halogen-free low smoke cross-linked polyethylene insulated thermoplastic polyolefin sheathed flame retardant shipboard power flexible cable, SC type/NC Type/NSC Type CJPJ/SC/NC/NSC

CJPJ80/SC/NC/NSC

CJPJ85/SC/NC/NSC

CJPJ90/SC/NC/NSC

CJPJ95/SC/NC/NSC

CJPJR/SC/NC/NSC halogen-free low smoke cross-linked polyethylene insulated cross-linked polyolefin sheathed flame-retardant shipboard power cable, SC/NC/NSC halogen-free low smoke cross-linked polyethylene insulated crosslinked polyolefin Naked copper wire braided flame-retardant shipboard power cable, SC/NC/NSC halogen-free low-smoke cross-linked polyethylene insulated cross-linked polyolefin inner sheathed copper wire braided cross-linked polyolefin sheathed flame-retardant shipboard power Cables, SC/NC/NSC Halogen-free Low Smoke Crosslinked Polyethylene Insulated Crosslinked Polyolefin Inner Naked Wire Braid Armored Fire-retardant Marine Power Cable, SC/NC/NSC Type Halogen-free Low Smoke Crosslinking Polyethylene insulated cross-linked polyolefin inner sheathed steel wire braided cross-linked polyolefin sheathed flame-retardant marine power cable, SC/NC/NSC type halogen-free low-smoke crosslinked polyethylene insulated cross-linked polyolefin sheathed flame-retardant boat Power Flexible Cables, SC Type/NC Type/NSC Type Note: The cable types not listed in this table can be composed according to the Q/NPDL035-2006 standard.

Table 3 PVC Insulated Marine Power Cables Common Models Product Models Product Name CVV/DA/SA/NA

CVV80/DA/SA/NA

CVV82/DA/SA/NA

CVV90/DA/SA/NA

CVV92/DA/SA/NA

CVVR/DA/SA/NA PVC insulated PVC sheathed marine power cable, DA type/SA type/NA type PVC insulated PVC inner sheathed bare copper wire braided shipboard power cable, DA type/ SA/NA type PVC insulated PVC inner sheathed copper wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type PVC insulated PVC inner sheathed bare steel wire braided shipboard Power cable, DA type/SA type/NA type PVC insulated PVC inner sheathed steel wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type PVC insulated PVC sheathed ship Power Flexible Cables, Type DA/SA/NA Note: The cable types not listed in this table can be composed according to the Q/NPDL035-2006 standard.

Table 4 Natural-Styrene-Butadiene Rubber Insulated Marine Power Cables Common Models Product Models Product Name CXF/DA/SA/NA

CXF80/DA/SA/NA

CXF82/DA/SA/NA

CXF90/DA/SA/NA

CXF92/DA/SA/NA

CXFR/DA/SA/NA

CXV/DA/SA/NA

CXV80/DA/SA/NA

CXV82/DA/SA/NACXV90/DA/SA/NA

CXV92/DA/SA/NA

CXVR/DA/SA/NA Natural butyl benzene insulated neoprene sheathed shipboard power cable, DA type/SA type/NA type natural butyl benzene insulated neoprene sleeve bare copper woven armored shipboard power cable, type DA/SA /NA natural styrene-butadiene rubber insulated neoprene inner sheathed copper wire braided PVC outer sheathed marine power cable, DA type/SA type/NA type natural butylbenzene insulated neoprene inner sheathed steel wire braided armored marine power cable, DA Type/SA Type/NA Type Natural butylbenzene Insulation Neoprene Inner Steel Wire Braided Armored PVC Jacket Marine Power Cable, DA Type/SA Type/NA Type Natural butyl Benzene Insulator Neoprene Jacket Marine Power Flexible Cable, Type DA /SA type/NA type natural butyl benzene insulated PVC sheathed marine power cable, DA type/SA type/NA type natural styrene butadiene insulated PVC inner sheath bare copper wire braided shipboard power cable, DA type/SA Type/NA type natural styrene-butadiene rubber insulated neoprene inner sheathed copper wire braided PVC outer sheathed shipboard power cable, DA type/SA type/NA type natural styrene-butadiene insulated PVC inner sheathed bare steel wire braided shipboard power cable ,DA type/SA type/NA type natural butyl benzene insulated PVC inner sheathed steel wire braided PVC outer sheathed shipboard power cable, DA type /SA type/NA type natural styrene-butadiene-insulated PVC sheathed marine power flexible cable, type DA/SA/NA type Note: The cable types not listed in this table can be formed in accordance with the specifications of Q/NPDL035-2006 .

V. Technical parameters 50W (HB/V level) 500W (5V level)

Flame height 20±1mm40±2mm

Blower standard IEC60695-11-4 IEC60695-11-3

Temperature detection MAX1050°C±0.1%MAX1050°C±0.1%

Gas flow 105±10ml/min965±30ml/min

Water column height<10mm125±5mm

Checking time 44±2S54±2S

Flow accuracy 1.5% 1.5%

Copper block weight 1.76g±0.01g10±0.05g

Gas Category Methane Methane

Tianjin Cable Plant Rubber Cable Factory Sales Manager: Ms. Xue

Contact: Manager

Hand machine

Office Phone

Sales department telephone

Sales office telephone

Fax

QQ

Factory Address: Liu Yanma Industrial Area, Dacheng County, Hebei Province

Organization Code Certificate-2
CCC Certification Number Business License Registration Number Remittance Account 05316
Bank: Liu Guxian Rural Credit Cooperative, Dacheng County, Hebei Province

I plant in the "customer is God" principle, "honest and trustworthy, warm and thoughtful" service concept has won the trust of the majority of merchants.

Pharmaceutical Factory Industrial Sectional Door

Pharmaceutical Factory Industrial Sectional Door,White Pharmaceutical Factory Industrial Sectional Door,Blue Pharmaceutical Factory Industrial Sectional Door,Red Pharmaceutical Factory Industrial Sectional Door

Shenzhen Yue Ma intelligent Technol , https://www.ymcleanroomdoor.com