Heating furnace grate stuck and its treatment

1) The installation quality of the sealing iron on both sides of the furnace wall is not good, or the overheat deformation produces unevenness, or is uneven and stuck.
2) When the grate is assembled, the control of the length of the tie rod is inconsistent and stuck.
3) The rotation between the splint and grate piece is inflexible. In operation, the grate piece is automatically dropped by the eagle iron card; the grate piece is too short, the splint blocker cannot lift the grate plate, resulting in the grate plate falling into between the two splints and stuck .
4) Metal inclusions or coke stuck in the coal.
5) The grate breaks or the pin on the clamp plate falls off and blocks the grate.
6) Grate beam bending.
7) Large shaft bush lacks oil.
8) The maintenance quality is poor, the front and rear axles are not parallel, so that the grate runs off.
9) Gearbox failure, stopping the grate. Handling method: According to the cause of the fault, carry out repairs. During regular maintenance, quality must be guaranteed.

CPF-X wall-mounted Chlorine Dioxide Generator is a new type of small Chlorine Dioxide Generating System which is suitable for the secondary water supply and the situations that need small capacity of chlorine dioxide. It has functions of flow rate/ residual chlorine dioxide on-line control, linkage running with water pump, giving low liquid level alarm of raw materials, remote start / stop control and uploading the working states and alarm signals; and giving acoustic and optical failure alarm etc.
*Related Products:portable chlorine dioxide.

Compact Chlorine Dioxide Generator

Chlorine Dioxide System, Chemical Chlorine Dioxide Generator, Clo2 Disinfection System

Nanjing Ligong Shuifu Environmental Protection Technology Co.,Ltd. , http://www.watermanclo2.com